Skip to content

Multiifo coincident rate estimation

Thomas Dent edited this page May 9, 2019 · 8 revisions

Multiifo coincident rate estimation

This page details the testing done to the coinc_rate.multiifo_noise_coinc_rate function to check that noise rates are being calculated correctly

3-detector coincidence calculation of trigger rates vs true (background) rates

Note that there is some 'blocking' (grouping of templates with similar duration) in order to obtain better statistics for the triple coincident events

3-detector coincidence overestimate of trigger rates

This 'overestimate' is the predicted rate divided by the true rate, there may be a small bias due to the true rate being an integer

2-detector coincidence calculation of trigger rates vs true (background) rates

2-detector coincidence overestimate of trigger rates

Mean H1L1 expected coincidence rate from some example runs

This rate can be used as a benchmark/constant standard for scaling rates from other ifo combinations and/or data periods to obtain numbers of order 1. Here we look at a few recent runs representative of 2-OGC or O3 production settings.

  • directory /home/tdent/o2/analysis/o3dev/a22/multiifo_20190406_klsgv/output

mean actual noise coinc rate per template = 4.5e-7 Hz

  • O2 a22: 15 splitbanks, random-sort, keep-loudest-interval=1, keep-loudest-num=100, coinc threshold 0.005

directory: /home/tdent/o2/analysis/o3dev/a22/multiifo_20190419_expfit_decim_shuffle2/output

mean expected rate per template in different coincidences:

HLV coincidences is 1.101e-10 Hz

HL coincidences is 4.563e-07 Hz

LV coincidences is 9.555e-07 Hz

HV coincidences is 9.750e-07 Hz

  • O2 a20: 15 splitbanks, random-sort keep-loudest-interval=1, keep-loudest-num=100, coinc threshold 0.005

directory: /home/tdent/o2/analysis/o3dev/a20/multiifo_20190419_expfit_decim_shuffle/output

mean expected rate per template in different coincidences:

HLV coincidences is 1.095e-10 Hz

HL coincidences is 4.550e-07 Hz

LV coincidences is 9.524e-07 Hz

HV coincidences is 9.712e-07 Hz

  • O3 a1: 20 splitbanks, mchirp-sort, keep-loudest-interval=1.072, keep-loudest-num=100, minimal DQ, coinc threshold 0.002

directory: /home/tdent/o3/analysis/c00_clean/hlv/a1/initial/output

Mean HL coincidences per template: 4.985e-07

Clone this wiki locally