Notifications
You must be signed in to change notification settings - Fork 9
2349: Setpoint Override
David Bonnes edited this page Mar 29, 2021
·
24 revisions
This packet has two distinct payload formats either 7 or 13 bytes long, dependant upon an optional trailing datetime field.
I --- 01:063844 --:------ 01:063844 2349 013 03070804FFFFFF0017030B07E4
I --- 01:063844 --:------ 01:063844 2349 007 06070800FFFFFF
Payload length 7: The following
W --- 22:081652 01:063844 --:------ 2349 007 01086600FFFFFF
I --- 01:063844 22:081652 --:------ 2349 007 01086600FFFFFF
The following was seen with a DTS92(E) that was placed into eco mode, which lasts for an hour.
20:17:07.669 043 W --- 22:081652 01:063844 --:------ 2349 007 0106400300003C
20:17:07.685 044 I --- 01:063844 22:081652 --:------ 2349 007 0106400300003C
20:20:07.649 042 RQ --- 22:081652 01:063844 --:------ 2349 007 01064003000039
20:20:07.666 044 RP --- 01:063844 22:081652 --:------ 2349 007 01064003000039
20:23:07.642 042 RQ --- 22:081652 01:063844 --:------ 2349 007 01064003000036
20:23:07.659 044 RP --- 01:063844 22:081652 --:------ 2349 007 01064003000036
...
21:11:07.623 044 RP --- 01:063844 22:081652 --:------ 2349 007 01064003000006
21:14:07.615 043 RQ --- 22:081652 01:063844 --:------ 2349 007 01064003000003
21:14:07.642 044 RP --- 01:063844 22:081652 --:------ 2349 007 01064003000003
You can see it start with a duration of 0x3C (60 in decimal), dropping regularly, and reaching 0x03 (3 in decimal) some 57 minutes later.
Payload length 13:
2020-11-03T21:32:35.019421 043 I --- 01:063844 --:------ 01:063844 2349 007 01086600FFFFFF
2020-11-03T21:35:37.843776 057 W --- 22:081652 01:063844 --:------ 2349 007 01086600FFFFFF
2020-11-03T21:35:37.860222 043 I --- 01:063844 22:081652 --:------ 2349 007 01086600FFFFFF
2020-11-03T21:35:48.389720 043 I --- 01:063844 --:------ 01:063844 2349 013 0101F404FFFFFF0017030B07E4
2020-11-03T21:41:10.398336 060 I --- 01:063844 --:------ 01:063844 2349 013 01086604FFFFFF0017030B07E4
2020-11-03T21:41:16.600527 058 I --- 01:063844 --:------ 01:063844 2349 007 01086600FFFFFF
2020-11-03T21:42:40.832053 055 W --- 22:070483 01:063844 --:------ 2349 007 06076C00FFFFFF
2020-11-03T21:42:40.854956 043 I --- 01:063844 --:------ 01:063844 2349 007 06070800FFFFFF
2020-11-03T21:42:40.882790 042 I --- 01:063844 22:070483 --:------ 2349 007 06070800FFFFFF
2020-11-03T21:42:42.492518 043 I --- 01:063844 --:------ 01:063844 2349 013 06070804FFFFFF0017030B07E4
2020-11-03T21:46:59.850895 042 I --- 01:063844 --:------ 01:063844 2349 007 06070800FFFFFF
2020-11-03T22:31:15.765656 042 I --- 01:063844 --:------ 01:063844 2349 013 0101F404FFFFFF0017030B07E4
This is the same example as above, but dashes have been added to the payload for readability:
I --- 01:063844 --:------ 01:063844 2349 013 03-0708-04-FFFFFF-0017030B07E4
I --- 01:063844 --:------ 01:063844 2349 007 06-0708-00-FFFFFF
Payload decode: | Split | |
---|---|---|
zone_idx | [0:2] | |
setpoint | [2:6] | in Celsius |
zone_mode | [6:8] | see notes below |
countdown | [8:14] | in minutes, for mode 03
|
time_until | [14:26] | a datetime, for mode 04
|
Zone mode is one of:
ZONE_MODE_FOLLOW_SCHEDULE = "00"
ZONE_MODE_ADVANCED_OVERRIDE = "01" # until the next scheduled setpoint
ZONE_MODE_PERMANENT_OVERRIDE = "02" # indefinitely
ZONE_MODE_COUNTDOWN_OVERRIDE = "03" # for a number of minutes
ZONE_MODE_TEMPORARY_OVERRIDE = "04" # until a given date/time
This is code to convert the time_until field into a datetime:
def dtm_from_hex(value: str) -> str: # from parsers
"""Convert a hex string to an (naive, local) isoformat string."""
# 00141B0A07E3 (...HH:MM:00) for system_mode, zone_mode (schedules?)
# 0400041C0A07E3 (...HH:MM:SS) for sync_datetime
if value == "FF" * 6:
return None
if len(value) == 12:
value = f"00{value}"
# assert len(value) == 14
return dt(
year=int(value[10:14], 16),
month=int(value[8:10], 16),
day=int(value[6:8], 16),
hour=int(value[4:6], 16) & 0b11111, # 1st 3 bits: DayOfWeek
minute=int(value[2:4], 16),
second=int(value[:2], 16) & 0b1111111, # 1st bit: used for DST
).strftime("%Y-%m-%d %H:%M:%S")
0001
RF Check0004
Zone name0008
Relay demand0009
Relay failsafe000A
Zone config000C
Zone actuators0016
RF signal test0100
Localisation0404
Zone schedule0418
System fault1030
Mix zone config1060
Battery state10A0
DHW setpoint10E0
Device info1100
Boiler relay info1260
DHW temperature12B0
Window sensor1F09
System Sync1F41
DHW mode1FC9
RF bind1FD4
Opentherm ticker22C9
UFH setpoint22D9
Boiler setpoint2309
Zone setpoint2349
Setpoint override2E04
Controller mode30C9
Zone temperature313F
System datetime3150
Heat demand3220
Opentherm message3B00
Actuator sync3EF0
Actuator info3EF1
Actuator unknown
0002
External sensor0005
Zone management0006
Schedule sync000E
Unknown01D0
Unknown01E9
Unknown042F
Unknown1280
Outdoor humidity1290
Outdoor temp12A0
Indoor humidity2249
Now/next setpoint22D0
UFH unknown22F1
Ventilation unit command22F3
Ventilation unit temp. high2389
Unknown2D49
Unknown3120
Unknown31D9
HVAC Unknown31DA
HVAC Unknown31E0
HVAC Unknown