This packet code is not known. If you know more - please add some information here.
These packets are spontaneously sent by round thermostats (T87RF) approximately every 3h 45m.
17:20:02.400 067 I --- 34:205645 --:------ 34:205645 3120 007 0070B0000000FF
21:00:54.763 062 I --- 34:205645 --:------ 34:205645 3120 007 0070B0000000FF
00:41:47.106 073 I --- 34:205645 --:------ 34:205645 3120 007 0070B0000000FF
22:47:01.429 081 I --- 34:205645 --:------ 34:205645 3120 007 0070B0000000FF
02:27:53.807 061 I --- 34:205645 --:------ 34:205645 3120 007 0070B0000000FF
The startup sequence for a Round Thermostat (T87RF) includes this packet, as well as device information, battery status, and zone config/setpoint packets:
22:05:29.383 045 I --- 34:092243 --:------ 34:092243 042F 008 0000000013001301
22:05:29.474 045 I --- 34:092243 63:262142 --:------ 10E0 038 000001C8380A0100...
22:05:29.515 045 I --- 34:092243 --:------ 34:092243 000E 003 000014
22:05:29.741 045 RQ --- 34:092243 01:145038 --:------ 000A 001 01
22:05:29.757 045 RP --- 01:145038 34:092243 --:------ 000A 006 011001F40DAC
22:05:29.836 045 I --- 34:092243 --:------ 34:092243 1060 003 00FF01
22:05:30.131 045 I --- 34:092243 --:------ 34:092243 3120 007 0070B0000000FF
22:05:32.155 045 RQ --- 34:092243 01:145038 --:------ 000A 001 01
22:05:32.171 045 RP --- 01:145038 34:092243 --:------ 000A 006 011001F40DAC
22:05:32.233 045 RQ --- 34:092243 01:145038 --:------ 2309 001 01
22:05:32.248 045 RP --- 01:145038 34:092243 --:------ 2309 003 0107D0
0001
RF Check0004
Zone name0008
Relay demand0009
Relay failsafe000A
Zone config000C
Zone actuators0016
RF signal test0100
Localisation0404
Zone schedule0418
System fault1030
Mix zone config1060
Battery state10A0
DHW setpoint10E0
Device info1100
Boiler relay info1260
DHW temperature12B0
Window sensor1F09
System Sync1F41
DHW mode1FC9
RF bind1FD4
Opentherm ticker22C9
UFH setpoint22D9
Boiler setpoint2309
Zone setpoint2349
Setpoint override2E04
Controller mode30C9
Zone temperature313F
System datetime3150
Heat demand3220
Opentherm message3B00
Actuator sync3EF0
Actuator info3EF1
Actuator unknown
0002
External sensor0005
Zone management0006
Schedule sync000E
Unknown01D0
Unknown01E9
Unknown042F
Unknown1280
Outdoor humidity1290
Outdoor temp12A0
Indoor humidity2249
Now/next setpoint22D0
UFH unknown22F1
Ventilation unit command22F3
Ventilation unit temp. high2389
Unknown2D49
Unknown3120
Unknown31D9
HVAC Unknown31DA
HVAC Unknown31E0
HVAC Unknown