Device 13: BDR91 Relay
David Bonnes edited this page Jul 11, 2020
·
4 revisions
18:17:08.008 074 I --- 13:081807 --:------ 13:081807 3EF0 003 0000FF
18:17:36.581 049 I --- 07:045960 --:------ 07:045960 1260 003 00097E
18:17:53.674 057 I --- 13:081807 --:------ 13:081807 3EF0 003 0000FF
18:18:00.898 056 I --- 01:145038 --:------ 01:145038 1FC9 018 FA-0008-06368E FC-3B00-06368E FA-1FC9-06368E
18:18:02.384 051 W --- 13:081807 01:145038 --:------ 1FC9 006 00-3EF0-353F8F
18:18:02.399 054 I --- 01:145038 13:081807 --:------ 1FC9 006 00-FFFF-06368E
A BDR91A relay is hard-wired and thus always listening for packets.
A BDR91A can be used as:
- a boiler relay (responds to a call for heat)
- a heat valve relay (as used with a combined CH/DHW systems)
- a relay for an Electric Zone (doesn't call for heat)
- a relay for a Zone Valve zone (as above, but calls for heat)
A BDR91A will respond to a RQ
sent to 0008
, 0016
, 1100
, 1FC9
, and 3EF1
:
095 RQ --- 18:013393 13:237335 --:------ 0008 001 00
060 RP --- 13:237335 18:013393 --:------ 0008 002 000A
095 RQ --- 18:013393 13:237335 --:------ 0016 001 00
059 RP --- 13:237335 18:013393 --:------ 0016 002 0012
095 RQ --- 18:013393 13:237335 --:------ 1100 001 00
055 RP --- 13:237335 18:013393 --:------ 1100 008 000C1400007FFF01
095 RQ --- 18:013393 13:237335 --:------ 3EF1 001 00
055 RP --- 13:237335 18:013393 --:------ 3EF1 007 00017F005300FF
Note that the RQ
s payload is ignored, and all RP
s have a domain_id
of 00
.
Specifically, BDR91A configured as a boiler relay will respond to a 1FC9
thus (dashes/spaces added to the payload for readability):
095 RQ --- 18:013393 13:237335 --:------ 1FC9 001 00
053 RP --- 13:237335 18:013393 --:------ 1FC9 012 00-3EF0-379F17 00-3B00-379F17
Whilst a BDR91A configured as a DHW valve will respond:
053 RP --- 13:106039 18:013393 --:------ 1FC9 006 00-3EF0-359E37
Note: The boiler relay payload includes a
3B00
, whilst the other relays do not.
Only commands up to 4000
have been tested.
0001
RF Check0004
Zone name0008
Relay demand0009
Relay failsafe000A
Zone config000C
Zone actuators0016
RF signal test0100
Localisation0404
Zone schedule0418
System fault1030
Mix zone config1060
Battery state10A0
DHW setpoint10E0
Device info1100
Boiler relay info1260
DHW temperature12B0
Window sensor1F09
System Sync1F41
DHW mode1FC9
RF bind1FD4
Opentherm ticker22C9
UFH setpoint22D9
Boiler setpoint2309
Zone setpoint2349
Setpoint override2E04
Controller mode30C9
Zone temperature313F
System datetime3150
Heat demand3220
Opentherm message3B00
Actuator sync3EF0
Actuator info3EF1
Actuator unknown
0002
External sensor0005
Zone management0006
Schedule sync000E
Unknown01D0
Unknown01E9
Unknown042F
Unknown1280
Outdoor humidity1290
Outdoor temp12A0
Indoor humidity2249
Now/next setpoint22D0
UFH unknown22F1
Ventilation unit command22F3
Ventilation unit temp. high2389
Unknown2D49
Unknown3120
Unknown31D9
HVAC Unknown31DA
HVAC Unknown31E0
HVAC Unknown