2349: Setpoint Override
David Bonnes edited this page Mar 29, 2021
·
24 revisions
2020-11-03T21:32:35.019421 043 I --- 01:063844 --:------ 01:063844 2349 007 01086600FFFFFF
2020-11-03T21:35:37.843776 057 W --- 22:081652 01:063844 --:------ 2349 007 01086600FFFFFF
2020-11-03T21:35:37.860222 043 I --- 01:063844 22:081652 --:------ 2349 007 01086600FFFFFF
2020-11-03T21:35:48.389720 043 I --- 01:063844 --:------ 01:063844 2349 013 0101F404FFFFFF0017030B07E4
2020-11-03T21:41:10.398336 060 I --- 01:063844 --:------ 01:063844 2349 013 01086604FFFFFF0017030B07E4
2020-11-03T21:41:16.600527 058 I --- 01:063844 --:------ 01:063844 2349 007 01086600FFFFFF
2020-11-03T21:42:40.832053 055 W --- 22:070483 01:063844 --:------ 2349 007 06076C00FFFFFF
2020-11-03T21:42:40.854956 043 I --- 01:063844 --:------ 01:063844 2349 007 06070800FFFFFF
2020-11-03T21:42:40.882790 042 I --- 01:063844 22:070483 --:------ 2349 007 06070800FFFFFF
2020-11-03T21:42:42.492518 043 I --- 01:063844 --:------ 01:063844 2349 013 06070804FFFFFF0017030B07E4
2020-11-03T21:46:59.850895 042 I --- 01:063844 --:------ 01:063844 2349 007 06070800FFFFFF
2020-11-03T22:31:15.765656 042 I --- 01:063844 --:------ 01:063844 2349 013 0101F404FFFFFF0017030B07E4
2020-02-29T13:31:12.779994 055 W --- 22:070483 01:063844 --:------ 2349 007 0607080300003C
2020-02-29T13:31:12.813097 044 I --- 01:063844 22:070483 --:------ 2349 007 0607080300003C
2020-02-29T13:34:12.739977 053 RQ --- 22:070483 01:063844 --:------ 2349 007 06070803000039
2020-02-29T13:34:12.782421 044 RP --- 01:063844 22:070483 --:------ 2349 007 06070803000039
Payload decode: | ||
---|---|---|
Zone/Device | [0:2] | zone_idx or domain_id (F9=CH, FA=DHW, FC=Boiler control) |
Demand | [2:4] | Heat demand (0-200) |
0001
RF Check0004
Zone name0008
Relay demand0009
Relay failsafe000A
Zone config000C
Zone actuators0016
RF signal test0100
Localisation0404
Zone schedule0418
System fault1030
Mix zone config1060
Battery state10A0
DHW setpoint10E0
Device info1100
Boiler relay info1260
DHW temperature12B0
Window sensor1F09
System Sync1F41
DHW mode1FC9
RF bind1FD4
Opentherm ticker22C9
UFH setpoint22D9
Boiler setpoint2309
Zone setpoint2349
Setpoint override2E04
Controller mode30C9
Zone temperature313F
System datetime3150
Heat demand3220
Opentherm message3B00
Actuator sync3EF0
Actuator info3EF1
Actuator unknown
0002
External sensor0005
Zone management0006
Schedule sync000E
Unknown01D0
Unknown01E9
Unknown042F
Unknown1280
Outdoor humidity1290
Outdoor temp12A0
Indoor humidity2249
Now/next setpoint22D0
UFH unknown22F1
Ventilation unit command22F3
Ventilation unit temp. high2389
Unknown2D49
Unknown3120
Unknown31D9
HVAC Unknown31DA
HVAC Unknown31E0
HVAC Unknown